CMX Thickness Gauge
A versatile ultrasonic CMX Thickness Gauge that combines the ability to measure wall thickness with or without coatings and simultaneously measure the coating itself. Time-based B-scan and large data storage capacity compliment the advanced features of this brand-new gauge.
Available in three models. Standard (CMX), with data logging (CMXDL) and with data logging, A-Scan and B-Scan display with three independent gates (CMXDL+)
Measurement Modes
- Coating on: Pulse-Echo Coating (PECT)
- Coating off: Pulse-Echo (P-E)
- Temp Comp: Pulse-Echo Temperature compensated (PETP)
- Thru-Paint: Echo-Echo (E-E)
- Coating Only: Coating (CT)
Features
- Auto Probe Recognition
- Auto Probe Zero
- Auto Temperature Compensation
- Adjustable Gain – (v-low, low, med, high, v-high)
- Time based B-Scan (cross section view)
- High Speed Scan
- High/Low Alarm – dynamic update of both
- Differential Mode
- Transducer Linearity Selector
- Material Chart
- 64 Custom Setup Capability
- Massive Data Storage (CMXDL & CMXDL+)
- (Graphics ON) 16,000+ readings, B-Scans, & gauge settings for every stored reading
- (Graphics OFF) 210,000+ readings – including material, coating, min & max for all readings
CMXDL+ with 2 display options
ELECTRONIC PLATFORM
- Powered by a 100MHz DSP platform using FPGA technology.
- Two Channels – Dual pulsers and receivers.
- Up to 140Hz pulse repetition rate.
- Adjustable gain settings – vlow, low, med, hi, vhi.
- Automatic gain control (AGC).
- Time corrected gain (TCG).
- Massive data storage (32 Megabit of non-volatile RAM).
- 1/8 VGA Grayscle Display (240 x 160 pixels), EL backlit (On/Off/Auto), update rate of 25 times per second.
- 1/4 VGA AMOLED Color Display (320 x 240 pixels), 125 Hz refresh rate.
Features
- A-Scan (RF waveform, +/- Rectified waveform), Time-Based B-Scan, and Large Digits.
- Pulse-Echo, Pulse-Echo w/Coating, Pulse-Echo w/Temperature Compensation,
- Echo-Echo, Echo-Echo Verify, & Coating Only.
- Automatic: probe zero, probe recognition, and temperature compensation.
- Stores up to 64 custom setups for specific applications.
- High Speed Scan of up to 50 readings per second.
- Audible/visual alarm with hi and lo limit settings.
- Built-in differential mode for QC inspections.
- Time based B-Scan feature for cross section material scans.
- Attenuator: 20db cut/boost.
- pulser: 50 volt cut/boost (100 – 200 volts).
- Data storage formats: Alpha numeric grid and sequential w/auto identifier.
- Windows PC software included.
- 2 year limited warranty.
Standard Kit Includes the Gauge with alkaline batteries, 1/4″ element diameter x 5.0 MHz Transducer on 4 foot long integral cable, 4 oz. bottle of ultrasonic gel Couplant, Operation Manual and foam lined plastic case.